Neohapsis is currently accepting applications for employment. For more information, please visit our website www.neohapsis.com or email hr@neohapsis.com |
From: IT Resource Center (support_feedback
us-support-mail.external.hp.com)Date: Sun May 05 2002 - 11:38:18 CDT
HP Support Information Digests
===============================================================================
o IT Resource Center World Wide Web Service
---------------------------------------------------
If you subscribed through the IT Resource Center and would
like to be REMOVED from this mailing list, access the
IT Resource Center on the World Wide Web at:
http://www.itresourcecenter.hp.com/
Login using your IT Resource Center User ID and Password.
Then select Support Information Digests (located under
Maintenance and Support). You may then unsubscribe from the
appropriate digest.
To download a patch referenced below, access the
IT Resource Center on the World Wide Web at:
http://www.itresourcecenter.hp.com/
Login using your IT Resource Center User ID and Password.
Then select Individual Patches (under Maintenance and Support)
to access the patch. You may also download a patch via anonymous
ftp(1) from ftp.itrc.hp.com.
===============================================================================
Digest Name: weekly MPE/iX 6.0 patch digest
Created: Sun May 5 3:05:23 PDT 2002
Table of Contents:
Document ID Title
--------------- -----------
MPELXJ7A Data Loss When Using TAR with MPE fixed ASCII Files
MPELXC3B Patch Description: Add New Disk Drive IDs To The IODFAULT Fi
MPEKXL8B Patch Description: io redirection from a byte stream emulate
MPEMX46A IODFAULT File For 6.0 To Replace Missing Legacy Devices (HP
The documents are listed below.
-------------------------------------------------------------------------------
Document ID: MPELXJ7A
Date Loaded: 20020429
Title: Data Loss When Using TAR with MPE fixed ASCII Files
Data Loss When Using TAR with MPE fixed ASCII Files
BY: MEL ROBERTSON - CSY Patch Coordinator
Patch Name: MPELXJ7A
Path Name: /mpe-ix_patches/c.60.00/MPELXJ7A
Patch Description: Data Loss When Using TAR with MPE fixed ASCII Files
Last Updated: 04/29/02
Date Entered: 02/21/01
Patch Status: Patch is General Release
SR Number:
5003-459925
Dependency SCO: None
Patch Files:
ORGFILE TARGFILE PATCH TYPE
------------------------------------------------------------------
ILOLXJ7A.MPELXJ7A.PATCHIX
L00LXJ7A.MPELXJ7A.PATCHIX
GENLXJ7A.MPELXJ7A.PATCHIX
REFLXJ7A.MPELXJ7A.PATCHIX
MPELXJ7A.MPELXJ7A.PATCHIX
AUTOPAT.HP31900A.PATCHXL
SHOWPTCH.HP31900A.PATCHXL
Patch Package Size: 1424 sectors
General Release Text:
Known Conflicts
===============
Not applicable
Patch-to-Patch Dependencies
===========================
Not applicable
External Symptoms, Cause, Fix Description
=========================================
When TARing to an archive, the last record of Fixed ASCII files is
truncated. The system displays the following error message:
TAR.HPBIN.SYS: write error on file "filename": System call error
This creates a data loss situation.
The problem is fixed by a change to the byte stream emulator.
Customer Environment Changes
============================
Not applicable
Hardware Dependencies
=====================
Not applicable
Software Product/Application Dependencies
=========================================
Not applicable
Product Version Information
===========================
See filename information for specific version changes for each module.
Dump Analysis
=============
Not applicable
Product Number/Name:
HP31900 MPE/IX
Product VUF: C.16.01
OS Release VUF: C.60.00
Fix Release Version: A
Supersedes:
( 0)MPELXJ7 A
( 1) MPEKXL8 B
Criticality:
(1) The system could experience a System failure without the patch.
Distribution Recommendation:
For a FOS product and should be installed on all systems.
Update Required: Yes
Special Instructions:
NO SPECIAL INSTRUCTIONS PROVIDED FOR THIS PATCH
Installation Instructions:
Before installing this patch, please review all instructions and the
Hewlett-Packard SupportLine User Guide or Your Hewlett-Packard Support
Terms and Conditions for precautions, scope of license, restrictions,
and limitation of liability and warranties.
There is a document which gives a detailed descripton of all tasks
required prior to installing your patch. Request this document from
HPSL using e-mail (command: send mpeguide) or download it from the web
Unless there are special instructions, logon as MANAGER.SYS and run
UNPACKP to unpackage and restore all files before installing your patch.
Note! Please back up your system before you patch.
-----End of Document ID: MPELXJ7A--------------------------------------------
Document ID: MPELXC3B
Date Loaded: 20020429
Title: Patch Description: Add New Disk Drive IDs To The IODFAULT Fi
Patch Description: Add New Disk Drive IDs To The IODFAULT Fi
BY: MEL ROBERTSON - CSY Patch Coordinator
Patch Name: MPELXC3B
Path Name: /mpe-ix_patches/c.60.00/MPELXC3B
Patch Description: Add New Disk Drive IDs To The IODFAULT File
Last Updated: 04/29/02
Date Entered: 10/02/00
Patch Status: Patch is General Superseded
SR Number:
8606-161607
Dependency SCO: None
Patch Files:
ORGFILE TARGFILE PATCH TYPE
------------------------------------------------------------------
IODLXC3B.MPELXC3B.PATCHIX IODFAULT.PUB.SYS RP
I00LXC3B.MPELXC3B.PATCHIX IODFDATA.PUB.SYS NC
GENLXC3B.MPELXC3B.PATCHIX
REFLXC3B.MPELXC3B.PATCHIX
MPELXC3B.MPELXC3B.PATCHIX
AUTOPAT.HP31900A.PATCHXL
Patch Package Size: 1504 sectors
General Release Text:
Known Conflicts
===============
Not applicable
Patch-to-Patch Dependencies
===========================
Not applicable
External Symptoms, Cause, Fix Description
=========================================
Add Disk Drives IDs to the IODFAULT.PUB.SYS File
9 GB HVD ST39236LC
18 GB SE ST318417N ST318416N ST136475LW
18 GB HVD ST318437LC ST318406LC ST318404LC
ST318452LC ST318436LC
18 GB FC ST318452FC
36 GB SE ST136475LW
36 GB HVD ST336737LC ST336706LC ST336704LC
ST336752LC ST136475WD
36 GB FC ST33605FC ST336752FC ST336704FC
72 GB HVD ST373405LC ST173404LC
72 GB FC ST373405FC ST173404FC
ST318406LW ST336706LW
Customer Environment Changes
============================
Not applicable
Hardware Dependencies
=====================
Not applicable
Software Product/Application Dependencies
=========================================
Not applicable
Product Version Information
===========================
See filename information for specific version changes for each module.
Dump Analysis
=============
Not applicable
Product Number/Name:
HP36395 POSIX 1003.1
HP31900 MPE/IX
Product VUF: C.16.01
OS Release VUF: C.60.00
Fix Release Version: B
Supersedes:
( 0)MPELXC3 B
( 1) MPELX59 B
( 2) MPELX40 B
( 3) MPELX30 B
( 4) MPELX10 B
( 5) MPEKXH0 E
Criticality:
(1) The system could experience a System failure without the patch.
Distribution Recommendation:
For a FOS product and should be installed on all systems.
Update Required: Yes
Special Instructions:
The group HPDCE.SYS must exist in order for this patch to be
installed successfully. If this group doesn't already exist,
create it using the following command:
:NEWGROUP HPDCE.SYS;CAP=BA,IA,PM,MR,DS,PH
This group should already be present on systems with MPE/iX 6.0
and later; on MPE/iX 5.5 systems however, this group may not
be present.
Installation Instructions:
Before installing this patch, please review all instructions and the
Hewlett-Packard SupportLine User Guide or Your Hewlett-Packard Support
Terms and Conditions for precautions, scope of license, restrictions,
and limitation of liability and warranties.
There is a document which gives a detailed descripton of all tasks
required prior to installing your patch. Request this document from
HPSL using e-mail (command: send mpeguide) or download it from the web
Unless there are special instructions, logon as MANAGER.SYS and run
UNPACKP to unpackage and restore all files before installing your patch.
Note! Please back up your system before you patch.
-----End of Document ID: MPELXC3B--------------------------------------------
Document ID: MPEKXL8B
Date Loaded: 20020429
Title: Patch Description: io redirection from a byte stream emulate
Patch Description: io redirection from a byte stream emulate
BY: MEL ROBERTSON - CSY Patch Coordinator
Patch Name: MPEKXL8B
Path Name: /mpe-ix_patches/c.60.00/MPEKXL8B
Patch Description: io redirection from a byte stream emulated file will cause
Last Updated: 04/29/02
Date Entered: 12/08/98
Patch Status: Patch is General Superseded
SR Number:
5003-437384 4701-346643
Dependency SCO: None
Patch Files:
ORGFILE TARGFILE PATCH TYPE
------------------------------------------------------------------
ILOKXL8B.MPEKXL8B.PATCHIX
L00KXL8B.MPEKXL8B.PATCHIX
GENKXL8B.MPEKXL8B.PATCHIX
REFKXL8B.MPEKXL8B.PATCHIX
MPEKXL8B.MPEKXL8B.PATCHIX
AUTOPAT.HP31900A.PATCHXL
SHOWPTCH.HP31900A.PATCHXL
Patch Package Size: 1424 sectors
General Release Text:
Known Conflicts
===============
Not applicable
Patch-to-Patch Dependencies
===========================
Not applicable
External Symptoms, Cause, Fix Description
=========================================
A session hang will occur when a byte emulated posix script file is
redirected in the following way:
sh.hpbin.sys < scriptfile
Any session/process, such as TurboStore, that tries to access
scriptfile will also hang.
Customer Environment Changes
============================
Not applicable
Hardware Dependencies
=====================
Not applicable
Software Product/Application Dependencies
=========================================
Not applicable
Product Version Information
===========================
See filename information for specific version changes for each module.
Dump Analysis
=============
Not applicable
Product Number/Name:
HP31900 MPE/IX
Product VUF: C.16.01
OS Release VUF: C.60.00
Fix Release Version: B
Supersedes:
( 0)MPEKXL8 B
Criticality:
(1) The system could experience a System failure without the patch.
Distribution Recommendation:
For a FOS product and should be installed on all systems.
Update Required: Yes
Special Instructions:
NO SPECIAL INSTRUCTIONS PROVIDED FOR THIS PATCH
Installation Instructions:
Before installing this patch, please review all instructions and the
Hewlett-Packard SupportLine User Guide or Your Hewlett-Packard Support
Terms and Conditions for precautions, scope of license, restrictions,
and limitation of liability and warranties.
There is a document which gives a detailed descripton of all tasks
required prior to installing your patch. Request this document from
HPSL using e-mail (command: send mpeguide) or download it from the web
Unless there are special instructions, logon as MANAGER.SYS and run
UNPACKP to unpackage and restore all files before installing your patch.
Note! Please back up your system before you patch.
-----End of Document ID: MPEKXL8B--------------------------------------------
Document ID: MPEMX46A
Date Loaded: 20020429
Title: IODFAULT File For 6.0 To Replace Missing Legacy Devices (HP
IODFAULT File For 6.0 To Replace Missing Legacy Devices (HP
BY: MEL ROBERTSON - CSY Patch Coordinator
Patch Name: MPEMX46A
Path Name: /mpe-ix_patches/c.60.00/MPEMX46A
Patch Description: IODFAULT File For 6.0 To Replace Missing Legacy Devices (HP
Last Updated: 04/29/02
Date Entered: 01/16/02
Patch Status: Patch is General Release
SR Number:
8606-232153
Dependency SCO: None
Patch Files:
ORGFILE TARGFILE PATCH TYPE
------------------------------------------------------------------
IODMX46A.MPEMX46A.PATCHIX IODFAULT.PUB.SYS RP
I00MX46A.MPEMX46A.PATCHIX IODFDATA.PUB.SYS NC
GENMX46A.MPEMX46A.PATCHIX
REFMX46A.MPEMX46A.PATCHIX
MPEMX46A.MPEMX46A.PATCHIX
AUTOPAT.HP31900A.PATCHXL
Patch Package Size: 1584 sectors
General Release Text:
Known Conflicts
===============
Not applicable
Patch-to-Patch Dependencies
===========================
Not applicable
External Symptoms, Cause, Fix Description
=========================================
Legacy device information was mistakenly removed
from the 6.0 IODFAULT.PUB.SYS file. This included
devices like the HP7980A Magnetic Tape Drive and other
HP-IB devices.
When trying to configure a device like the HP 7980A
error messages would be returned saying the device is
not supported.
This problem was introduced in patch MPELXL1A and carried
forward into MPELXQ3A. This replacement patch is specific
to 6.0.
Customer Environment Changes
============================
Not applicable
Hardware Dependencies
=====================
Not applicable
Software Product/Application Dependencies
=========================================
Not applicable
Product Version Information
===========================
See filename information for specific version changes for each module.
Dump Analysis
=============
Not applicable
Product Number/Name:
HP31900 MPE/IX
Product VUF: C.16.01
OS Release VUF: C.60.00
Fix Release Version: A
Supersedes:
( 0)MPEMX46 A
( 1) MPELXQ3 A
( 2) MPELXL1 A
( 3) MPELXC3 B
( 4) MPELX59 B
( 5) MPELX40 B
( 6) MPELX30 B
( 7) MPELX10 B
( 8) MPEKXH0 E
Criticality:
(1) The system could experience a System failure without the patch.
Distribution Recommendation:
For a FOS product and should be installed on all systems.
Update Required: Yes
Special Instructions:
NO SPECIAL INSTRUCTIONS PROVIDED FOR THIS PATCH
Installation Instructions:
Before installing this patch, please review all instructions and the
Hewlett-Packard SupportLine User Guide or Your Hewlett-Packard Support
Terms and Conditions for precautions, scope of license, restrictions,
and limitation of liability and warranties.
There is a document which gives a detailed descripton of all tasks
required prior to installing your patch. Request this document from
HPSL using e-mail (command: send mpeguide) or download it from the web
Unless there are special instructions, logon as MANAGER.SYS and run
UNPACKP to unpackage and restore all files before installing your patch.
Note! Please back up your system before you patch.
-----End of Document ID: MPEMX46A--------------------------------------------
- Messages sorted by: [ date ] [ thread ] [ subject ] [ author ]